GSTDTAP
项目编号1736864
Collaborative Research: Self-Calibrating pH Sensors for Autonomous Collection of Climate Quality Data
Yuichiro Takeshita
主持机构Monterey Bay Aquarium Research Institute
项目开始年2017
2017-09-01
项目结束日期2020-08-31
资助机构US-NSF
项目类别Standard Grant
项目经费107817(USD)
国家美国
语种英语
英文摘要Autonomous pH sensors are becoming increasingly common in Ocean Acidification and Carbon Cycle studies. However, the value of experimental results and conclusions from these studies hinges directly on the reliability of pH data collected. Drawing on terminology from the field of meteorology, marine chemists and biologists categorize pH measurement accuracy as "Weather Quality" or "Climate Quality," corresponding to a level of roughly 0.02 or 0.003 pH units, respectively. While necessary in order to detect climate scale changes in pH, achievement of "Climate Quality" pH data from sensors remains elusive. The researchers propose to develop a robust, low maintenance, user friendly system that will allow climate quality data to be routinely collected from pH sensors on research vessels and oceanographic moorings. In essence, this project involves developing an automated self-calibrating pH sensor package that can be deployed by researchers that may not hold the expertise to achieve a climate quality dataset. Field tests will generate data in support of ongoing research programs involving shipboard underway measurements (e.g. CalCOFI) as well as autonomous in situ measurements at coastal sites including a local lagoon (Agua Hedionda, Carlsbad, CA) and a remote coral reef (Palmyra Atoll). The addition of climate quality pH data in these studies will broaden our understanding of long-term climate scale effects on, for example, oyster shellfisheries and coral reefs.

Based on previous efforts to outline Best Practices and Quality Control protocols for in situ pH sensor data, a central theme has emerged: independent validation of autonomous pH sensor measurements is required in order to generate climate quality datasets. Historically, this has been accomplished through painstaking work involving repeat bottle samples in the field. Sustaining a bottle sampling program is expensive and beyond the capabilities of many research labs that wish to measure high-frequency pH in the field. Even the most thorough field programs haven't managed to fully eliminate spatiotemporal mismatch between sensor and bottle samples, leading to significant uncertainty in the calibration of the sensor. Directly addressing this challenge, the objective of this work is to improve the quality of future Durafet pH sensor datasets via a built-in self-calibration function. Specifically, the project will integrate on-board, standardized Tris buffers in artificial seawater for periodic validation of pH sensor performance. As a natural result, addition of this capability will improve data quality and substantially reduce the efforts required by operators during a field deployment, as they will no longer be required to collect and analyze bottle samples for pH validation. Similar protocols have been successfully adapted for climate quality pCO2 measurement.
文献类型项目
条目标识符http://119.78.100.173/C666/handle/2XK7JSWQ/71684
专题环境与发展全球科技态势
推荐引用方式
GB/T 7714
Yuichiro Takeshita.Collaborative Research: Self-Calibrating pH Sensors for Autonomous Collection of Climate Quality Data.2017.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Yuichiro Takeshita]的文章
百度学术
百度学术中相似的文章
[Yuichiro Takeshita]的文章
必应学术
必应学术中相似的文章
[Yuichiro Takeshita]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。