Global S&T Development Trend Analysis Platform of Resources and Environment
DOI | 10.2172/978518 |
报告编号 | PNNL-19262;RPT-STMON-002, Rev. 0 |
来源ID | OSTI ID: 978518 |
Assessment of the Building 3430 Filtered Exhaust Stack Sampling Probe Location | |
Glissmeyer, John A. | |
2010-04-13 | |
出版年 | 2010 |
语种 | 英语 |
国家 | 美国 |
领域 | 地球科学 |
英文摘要 | Pacific Northwest National Laboratory performed a demonstration to determine the acceptable location in which to place an air sampling probe for emissions monitoring for radionuclides in the exhaust air discharge from the new 3430 Building Filtered Pathway Stack . The method was to adopt the results of a previously performed test series for a system of similar configuration, followed by a partial test on the actual system to verify the applicability of previously performed tests. The qualification criteria included 1) a uniform air velocity, 2) an average flow angle that does not deviate from the axis of the duct by more than 20°, 3) a uniform concentration of tracer gases, and 4) a uniform concentration of tracer particles. Section 1 provides background information for the demonstration, and Section 2 describes the test strategy, including the criteria for the applicability of model results and the test matrix. Section 3 describes the flow angle test and the velocity uniformity test, Section 4 provides the test results, and Section 5 provides the conclusions. Appendix A includes the test data sheets, and Appendix B gives applicable qualification results from the previously tested model stack. The data from the previously tested and similarly designed stack was demonstrated to be applicable to the current design for the 3430 Building Filtered Pathway stack. Therefore, this new system also meets the qualification criteria given in the ANSI/HPS N13.1 standard. Changes to the system configuration or operations outside of the bounds of this report (e.g., exhaust velocity increases, relocation of sample probe) will require retesting/reevaluation to determine compliance to the requirements. |
英文关键词 | stack sampling effluent air sampling for radionuclides air sampling |
URL | 查看原文 |
来源平台 | US Department of Energy (DOE) |
引用统计 | |
文献类型 | 科技报告 |
条目标识符 | http://119.78.100.173/C666/handle/2XK7JSWQ/4764 |
专题 | 地球科学 |
推荐引用方式 GB/T 7714 | Glissmeyer, John A.. Assessment of the Building 3430 Filtered Exhaust Stack Sampling Probe Location,2010. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Glissmeyer, John A.]的文章 |
百度学术 |
百度学术中相似的文章 |
[Glissmeyer, John A.]的文章 |
必应学术 |
必应学术中相似的文章 |
[Glissmeyer, John A.]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论