GSTDTAP  > 地球科学
DOI10.1016/j.atmosres.2017.06.026
Performance assessment of Beijing Lightning Network (BLNET) and comparison with other lightning location networks across Beijing
Srivastava, Abhay1; Tian, Ye1,4; Qie, Xiushu1,3,4; Wang, Dongfang1,4; Sun, Zhuling1; Yuan, Shanfeng1,4; Wang, Yu5; Chen, Zhixiong1,4; Xu, Wenjing2; Zhang, Hongbo1,4; Jiang, Rubin1,3; Su, Debin2
2017-11-15
发表期刊ATMOSPHERIC RESEARCH
ISSN0169-8095
EISSN1873-2895
出版年2017
卷号197
文章类型Article
语种英语
国家Peoples R China
英文摘要

The performances of Beijing Lightning Network (BLNET) operated in Beijing-Tianjin-Hebei urban cluster area have been evaluated in terms of detection efficiency and relative location accuracy. A self-reference method has been used to show the detection efficiency of BLNET, for which fast antenna waveforms have been manually examined. Based on the fast antenna verification, the average detection efficiency of BLNET is 97.4% for intracloud (IC) flashes, 73.9% for cloud-to-ground (CG) flashes and 93.2% for the total flashes. Result suggests the CG detection of regional dense network is highly precise when the thunderstorm passes over the network; however it changes day to day when the thunderstorms are outside the network. Further, the CG stroke data from three different lightning location networks across Beijing are compared. The relative detection efficiency of World Wide Lightning Location Network (WWLLN) and Chinese Meteorology Administration - Lightning Detection Network (CMA-LDN, also known as ADTD) are approximately 12.4% (16.8%) and 36.5% (49.4%), respectively, comparing with fast antenna (BLNET). The location of BLNET is in middle, while WWLLN and CMA-LDN average locations are southeast and northwest, respectively. Finally, the IC pulses and CG return stroke pulses have been compared with the S-band Doppler radar. This type of study is useful to know the approximate situation in a region and improve the performance of lightning location networks in the absence of ground truth. Two lightning flashes occurred on tower in the coverage of BLNET show that the horizontal location error was 52.9 m and 250 m, respectively.


英文关键词Lightning location network Intracloud flashes Cloud-to-ground flashes Location accuracy Detection efficiency
领域地球科学
收录类别SCI-E
WOS记录号WOS:000412250700005
WOS关键词SFERIC ARRAY LASA ; EASTERN NEW-YORK ; DETECTION EFFICIENCY ; ACCURACY ; SYSTEM ; WWLLN ; CLIMATOLOGY ; UPGRADE ; EUROPE ; POLAND
WOS类目Meteorology & Atmospheric Sciences
WOS研究方向Meteorology & Atmospheric Sciences
引用统计
文献类型期刊论文
条目标识符http://119.78.100.173/C666/handle/2XK7JSWQ/38564
专题地球科学
作者单位1.Chinese Acad Sci, Inst Atmospher Phys, Key Lab Middle Atmosphere & Global Environm Obser, Beijing 100029, Peoples R China;
2.China Meteorol Adm, Inst Urban Meteorol, Beijing 100089, Peoples R China;
3.Nanjing Univ Informat Sci & Technol, Collaborat Innovat Ctr Forecast & Evaluat Meteoro, Nanjing 21004, Jiangsu, Peoples R China;
4.Univ Chinese Acad Sci, Coll Earth Sci, Beijing, Peoples R China;
5.Wuhan NARI Ltd Co, State Grid Elect Power Res Inst, Wuhan, Hubei, Peoples R China
推荐引用方式
GB/T 7714
Srivastava, Abhay,Tian, Ye,Qie, Xiushu,et al. Performance assessment of Beijing Lightning Network (BLNET) and comparison with other lightning location networks across Beijing[J]. ATMOSPHERIC RESEARCH,2017,197.
APA Srivastava, Abhay.,Tian, Ye.,Qie, Xiushu.,Wang, Dongfang.,Sun, Zhuling.,...&Su, Debin.(2017).Performance assessment of Beijing Lightning Network (BLNET) and comparison with other lightning location networks across Beijing.ATMOSPHERIC RESEARCH,197.
MLA Srivastava, Abhay,et al."Performance assessment of Beijing Lightning Network (BLNET) and comparison with other lightning location networks across Beijing".ATMOSPHERIC RESEARCH 197(2017).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Srivastava, Abhay]的文章
[Tian, Ye]的文章
[Qie, Xiushu]的文章
百度学术
百度学术中相似的文章
[Srivastava, Abhay]的文章
[Tian, Ye]的文章
[Qie, Xiushu]的文章
必应学术
必应学术中相似的文章
[Srivastava, Abhay]的文章
[Tian, Ye]的文章
[Qie, Xiushu]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。