GSTDTAP  > 气候变化
DOI10.1111/gcb.15986
A new open-path eddy covariance method for nitrous oxide and other trace gases that minimizes temperature corrections
Da Pan; Ilya Gelfand; Lei Tao; Michael Abraha; Kang Sun; Xuehui Guo; Jiquan Chen; G. Philip Robertson; Mark A. Zondlo
2021-12-03
发表期刊Global Change Biology
出版年2021
英文摘要

Low-power, open-path gas sensors enable eddy covariance (EC) flux measurements in remote areas without line power. However, open-path flux measurements are sensitive to fluctuations in air temperature, pressure, and humidity. Laser-based, open-path sensors with the needed sensitivity for trace gases like methane (CH4) and nitrous oxide (N2O) are impacted by additional spectroscopic effects. Corrections for these effects, especially those related to temperature fluctuations, often exceed the flux of gases, leading to large uncertainties in the associated fluxes. For example, the density and spectroscopic corrections arising from temperature fluctuations can be one or two orders of magnitude greater than background N2O fluxes. Consequently, measuring background fluxes with laser-based, open-path sensors is extremely challenging, particularly for N2O and gases with similar high-precision requirements. We demonstrate a new laser-based, open-path N2O sensor and a general approach applicable to other gases that minimizes temperature-related corrections for EC flux measurements. The method identifies absorption lines with spectroscopic effects in the opposite direction of density effects from temperature and, thus, density and spectroscopic effects nearly cancel one another. The new open-path N2O sensor was tested at a corn (Zea mays L.) field in Southwestern Michigan, United States. The sensor had an optimal precision of 0.1 ppbv at 10 Hz and power consumption of 50 W. Field trials showed that temperature-related corrections were 6% of density corrections, reducing EC random errors by 20-fold compared to previously examined lines. Measured open-path N2O EC fluxes showed excellent agreement with those made with static chambers (m = 1.0 ± 0.3; r2 = .96). More generally, we identified absorption lines for CO2 and CH4 flux measurements that can reduce the temperature-related corrections by 10–100 times compared to existing open-path sensors. The proposed method provides a new direction for future open-path sensors, facilitating the expansion of accurate EC flux measurements.

领域气候变化 ; 资源环境
URL查看原文
引用统计
文献类型期刊论文
条目标识符http://119.78.100.173/C666/handle/2XK7JSWQ/343042
专题气候变化
资源环境科学
推荐引用方式
GB/T 7714
Da Pan,Ilya Gelfand,Lei Tao,et al. A new open-path eddy covariance method for nitrous oxide and other trace gases that minimizes temperature corrections[J]. Global Change Biology,2021.
APA Da Pan.,Ilya Gelfand.,Lei Tao.,Michael Abraha.,Kang Sun.,...&Mark A. Zondlo.(2021).A new open-path eddy covariance method for nitrous oxide and other trace gases that minimizes temperature corrections.Global Change Biology.
MLA Da Pan,et al."A new open-path eddy covariance method for nitrous oxide and other trace gases that minimizes temperature corrections".Global Change Biology (2021).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Da Pan]的文章
[Ilya Gelfand]的文章
[Lei Tao]的文章
百度学术
百度学术中相似的文章
[Da Pan]的文章
[Ilya Gelfand]的文章
[Lei Tao]的文章
必应学术
必应学术中相似的文章
[Da Pan]的文章
[Ilya Gelfand]的文章
[Lei Tao]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。