GSTDTAP  > 资源环境科学
DOI10.1038/s41467-017-00347-4
Electrical pulse-induced electrochemical biosensor for hepatitis E virus detection
Chowdhury, Ankan Dutta1; Takemura, Kenshin2; Li, Tian-Cheng3; Suzuki, Tetsuro4; Park, Enoch Y.1,2
2019-08-19
发表期刊NATURE COMMUNICATIONS
ISSN2041-1723
出版年2019
卷号10
文章类型Article
语种英语
国家Japan
英文摘要

Hepatitis E virus (HEV) is one of the leading causes of acute viral hepatitis worldwide. In this work, a pulse-triggered ultrasensitive electrochemical sensor was fabricated using graphene quantum dots and gold-embedded polyaniline nanowires, prepared via an interfacial polymerization and then self-assembly approach. Introducing an external electrical pulse during the virus accumulation step increases the sensitivity towards HEV due to the expanded surface of the virus particle as well as the antibody-conjugated polyaniline chain length, compared to other conventional electrochemical sensors. The sensor was applied to various HEV genotypes, including G1, G3, G7 and ferret HEV obtained from cell culture supernatant and in a series of fecal specimen samples collected from G7 HEV-infected monkey. The sensitivity is similar to that detected by real-time quantitative reverse transcription-polymerase chain (RT-qPCR). These results suggests that the proposed sensor can pave the way for the development of robust, high-performance sensing methodologies for HEV detection.


领域资源环境
收录类别SCI-E
WOS记录号WOS:000481607000007
WOS关键词GRAPHENE QUANTUM DOTS ; IN-SITU GROWTH ; IMPEDIMETRIC BIOSENSOR ; SENSITIVE DETECTION ; SELECTIVE DETECTION ; GOLD NANOPARTICLES ; INFLUENZA-VIRUS ; OXIDE ; GLUCOSE ; ASSAY
WOS类目Multidisciplinary Sciences
WOS研究方向Science & Technology - Other Topics
URL查看原文
引用统计
文献类型期刊论文
条目标识符http://119.78.100.173/C666/handle/2XK7JSWQ/203408
专题资源环境科学
作者单位1.Shizuoka Univ, Res Inst Green Sci & Technol, Suruga Ku, 836 Ohya, Shizuoka 4228529, Japan;
2.Shizuoka Univ, Grad Sch Sci & Technol, Dept Biosci, Suruga Ku, 836 Ohya, Shizuoka 4228529, Japan;
3.Natl Inst Infect Dis, Dept Virol 2, 4-7-1 Gakuen, Musashimurayam, Tokyo 2080011, Japan;
4.Hamamatsu Univ Sch Med, Dept Infect Dis, Hamamatsu, Shizuoka 4313125, Japan
推荐引用方式
GB/T 7714
Chowdhury, Ankan Dutta,Takemura, Kenshin,Li, Tian-Cheng,et al. Electrical pulse-induced electrochemical biosensor for hepatitis E virus detection[J]. NATURE COMMUNICATIONS,2019,10.
APA Chowdhury, Ankan Dutta,Takemura, Kenshin,Li, Tian-Cheng,Suzuki, Tetsuro,&Park, Enoch Y..(2019).Electrical pulse-induced electrochemical biosensor for hepatitis E virus detection.NATURE COMMUNICATIONS,10.
MLA Chowdhury, Ankan Dutta,et al."Electrical pulse-induced electrochemical biosensor for hepatitis E virus detection".NATURE COMMUNICATIONS 10(2019).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Chowdhury, Ankan Dutta]的文章
[Takemura, Kenshin]的文章
[Li, Tian-Cheng]的文章
百度学术
百度学术中相似的文章
[Chowdhury, Ankan Dutta]的文章
[Takemura, Kenshin]的文章
[Li, Tian-Cheng]的文章
必应学术
必应学术中相似的文章
[Chowdhury, Ankan Dutta]的文章
[Takemura, Kenshin]的文章
[Li, Tian-Cheng]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。