GSTDTAP  > 气候变化
A zero emission concept analysis of a single family house: Part 2 sensitivity analysis
Houlihan Wiberg, Aoife Anne Marie; Georges, Laurent; Fufa, Selamawit Mamo; Risholt, Birgit Dagrun; Good, Clara Stina
2015
出版年2015
语种英语
国家挪威
出版者SINTEF Academic Press
领域气候变化
英文摘要This report presents the results from a sensitivity analysis regarding the influence of using emission data from Norwegian EPD’s instead of the generic data from Ecoinvent, using different CO2eq-factors (for electricity in the operational phase) and electricity load from household appliances on the overall ZEB residential building performance. The materials which contribute the most to the embodied greenhouse gas emissions in the original ZEB concept residential building were selected [1]. The sensitivity analysis is performed by replacing the generic Ecoinvent data with Norwegian EPD data where available. Even though the embodied emissions from PV contribute the most emissions, they are not included in this analysis due to the lack of Norwegian EPD data for PV. Instead, the influence of different PV technologies and different module orientations on the embodied and avoided emissions is incorporated. Even if the calculation of embodied emission has uncertainties, the results indicate the annual embodied emissions reduction from 7.2 kg CO2eq/m2 to 5.8 kg CO2eq/m2 when the generic data is replaced with Norwegian EPD data. In addition, the sensitivity study investigates the influence of CO2eq-factors for electricity in the operational phase on the emission balance. Furthermore, the analysis discusses the energy consumption of electric appliances and how it could be reduced through more efficient products, especially the hot-fed machines (i.e. washing machines, tumble dryer and dishwasher). The ZEB Centre has chosen an average CO2eq factor of 132 g CO2eq/KWh for electricity in the operational phase of the building's lifetime of sixty years. ZEB ambition level ZEB-OM can still not be reached for the residential concept building. However, to choose higher European CO2eq factors make it possible to achieve this ambition. In further work, the calculation of embodied emissions using Norwegian EPD data for other construction materials should be incorporated. In the second stage of the work, the system boundary should be extended to include end of life emissions. There is further potential to reduce the embodied emissions by considering the biogenic carbon stored in wood products and the use of alternative building materials should also be considered. In addition, further work is thus required to define the potential energy saving that would result from a shift of standard appliances to high-performance appliances with better energy efficiency.
URL查看原文
来源平台Center for International Climate and Environmental Research-Oslo (CICERO)
文献类型科技报告
条目标识符http://119.78.100.173/C666/handle/2XK7JSWQ/2015
专题气候变化
推荐引用方式
GB/T 7714
Houlihan Wiberg, Aoife Anne Marie,Georges, Laurent,Fufa, Selamawit Mamo,et al. A zero emission concept analysis of a single family house: Part 2 sensitivity analysis:SINTEF Academic Press,2015.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Houlihan Wiberg, Aoife Anne Marie]的文章
[Georges, Laurent]的文章
[Fufa, Selamawit Mamo]的文章
百度学术
百度学术中相似的文章
[Houlihan Wiberg, Aoife Anne Marie]的文章
[Georges, Laurent]的文章
[Fufa, Selamawit Mamo]的文章
必应学术
必应学术中相似的文章
[Houlihan Wiberg, Aoife Anne Marie]的文章
[Georges, Laurent]的文章
[Fufa, Selamawit Mamo]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。